Major components of pre-fabricated Modular operation theatre

2023-04-17

Latest company news about Major components of pre-fabricated Modular operation theatre

Major components of pre-fabricated Modular operation theatre:

  • Operation theatre wall and ceiling Panels : Modular Operation Theatre wall panel 50mm thk and ceiling Panel 30mm thk will be constructed using 0.8mm EGP Steel sandwich panel with core consisting of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40 kg/m3
  • Antibacterial Paint layer :- Antibacterial Paint one primer coat along with two coats of Antibacterial & Antifungal Paint coating system ,which protects against the growth of micro-organism, such as mould ,funbgi, yeast and bacteria on its surface. Meets with Fire safety Norms and a minimum dry film thickness of 300 microns.
  • Vinyl ESD Flooring :- Seamless Conductive Flooring System (100% recyclable), having thk of 2mm, this tile is chemical resistant & anti bacterial & anti fungal property resistance. with perfectly curved flush covings, all joints covered properly hot welded with the same material.
  • Laminar air flow system : Laminar air Flow 2400X24000 mm (Planair Ceiling system) with unidirectional airflow. Plenum unit, Holding structure & Top plenum are made of Aluminium Sheet 1.6mm thk. with hepa filter having efficiency 99.97% down to 0.3 micron.. The laminar flow system shall have such design that it provides “S” class Hepa filter . The filter housing terminals are made of a one pice frame and plenum with perfact thightness features with Diffuser .
  • OT Surgeon control panel : Surgeon control panel membrance type Operation Theatre Control Panel (6 service Tiles) mounted flush in the theatre wall with Electrical Distribution Board complete with all accessories etc. The control panel comprising of the following :-
    I) 1 no Day Time Digital Clock
    II) 1 no Elapsed Time Digital Clock
    III) 1 no Hands Free Telephone
    IV) Medical Gas Alarm ( 5 gas )
    V) Temperature & Humidity display control ( Optional : Pressure difference )
    VI) Peripheral Light Control and Optional Radio/FM music
  • X- Ray View screen : Two Plate Dimmable LED X-Ray viewing screen ( Dimming range 3 – 100% Flicker free) ) complete with all accessories etc.
  • Ceiling Medical & Surgical pendants : Signle Arm or Double Arm Pendent with 800+ 800 mm Console with six electrical sockets 5/15 ampere, Two monitor shelf and 6 nos. of gas outlets option
  • Peripheral light : Recess mounted IP54 protocol, non-hygroscopic based Peripheral Lights to be mounted on falce ceiling for clean room application and digital dimmable ballast.
  • Writing or list board : OT Operating writing List Board of size 948mm X 648mm complete with all accessories.
  • Operation theatre door Automatic /Manual : Automatic or Manual hermatically sealed Sliding Door (1500mm wide 2100mm height), Open/Closing Door complete with glass vision window of 300mm x 300mm, alongwith all necessary accessories etc.
  • Pressure relief damper (PRD) :- Pressure Relief Dampers having made out SS304, 1.5mm thick & the multiple blades also made of 304 graded stainless steel with sleeve & aluminum grill for maintaining the positive pressure inside the operation theatre complete with all accessories etc.
  • Storage Unit : Storage Unit size of (1665mm x 865mm x 350mm) made of 1.5mm EGP 120 GSM Zinc coated steel complete with all accessories etc.
  • Air Conditioning with Humidity and Temperature Control : 4000 or 3000 CFM AHU with Condensing Unit as per requirement , System & Condensing Unit with 100% Fresh Air, Static Pressure – 125. With double blower.FAN SECTION – KRUGER/ NIKOTRA MOTOR – CROMPTON GREAVES / ABB / BHARAT BIJLI (B) Condensing Unit : micro Processor controlled Air Cooled Condensing Unit of 11 TR ( 5.5 +5.5) , hermetically sealed scroll compressor for R-22, refrigerant, complete with motor, condenser, fan of 3 phase connection. (VOLTAS/ BLUESTAR/HITACHI/ OTHER ) (C) Electrical Control Panel with Interlocking of AHU, CU, Thermostatic Volt Meter with temperature control interlocking system
  • Aluminum Ducting :- Aluminum Ducting ( 22 * 24 gauge ) with curves & bends where indicated for easy flow of air tight by applying silicon sealant after fabrication. Hangers will be provided to ducts & will be suspended be means of G.I. coated rod & these will not be more than 2.5 mtrs apart. Thermal insulation with 9mm XPE with aluminum foil for supply & return air ducts. Joints will be lapped with Nitrile tape for better insulation.
  • Dirty hatch or pass box
  • Electrical Distribution board
  • Operation theatre table
  • Operation theatre Surgical light
  • Scrub station
  • Other Electrical equipments